- Home
- Generator Size Calculator
Generator Size Calculator
Pick the appliances that must run at the same time. The calculator adds running watts, adds the one largest starting surge, leaves headroom and names the generator size to look for.
A fridge, a 1/2 HP sump pump, a furnace blower, six LED bulbs, Wi-Fi and a TV run at 2,760 W and peak at 3,860 W when the pump starts. With 20% headroom that is a 5,000 W generator.
What will run at the same time?
| Appliance | Run W | Start W | Qty |
|---|
- Running load
- 2,760 W
- Peak at start-up
- 3,860 W
- Needed with headroom
- 4,632 W
- Same size in kVA (pf 0.8)
- 6.3
Biggest start-up kick: —. Start that appliance first, then the rest.
Wattages are typical upper-end values from generator makers' charts; the nameplate on your appliance or motor wins. Not sure what yours draw? See the appliance wattage chart.
Generator size for common backup plans
Each row adds one more load to the one above. Peak is the running total plus the single largest starting surge in the set.
| What runs together | Running | Peak | Buy at least |
|---|---|---|---|
| Lights, fridge, Wi-Fi, phones | 610 W | 1,410 W | 2,000 W |
| + sump pump (1/2 HP) | 1,660 W | 2,760 W | 3,500 W |
| + furnace blower (gas heat) | 2,460 W | 3,560 W | 4,500 W |
| + well pump (1/2 HP) | 3,460 W | 4,560 W | 6,500 W |
| + 10,000 BTU window AC | 3,860 W | 5,060 W | 6,500 W |
| Most of a house: central AC 3 ton, water heater | 11,700 W | 14,200 W | 17,500 W |
What a generator of each size can start
The heaviest single loads each size can start on its own, with nothing else running. Real use is a mix, so treat this as a ceiling, not a plan.
| Generator | Largest single loads it can start | Continuous limit (80%) |
|---|---|---|
| 2,000 W | Well pump, Furnace blower fan, Sump pump | 1,600 W |
| 3,500 W | RV air conditioner, 13,500 BTU, Refrigerator, Electric range, one burner | 2,800 W |
| 5,000 W | Air compressor, Well pump, Circular saw, 7-1/4 in | 4,000 W |
| 7,500 W | Central AC, 3 ton, Electric clothes dryer, Electric water heater | 6,000 W |
| 10,000 W | Central AC, 3 ton, Electric clothes dryer, Electric water heater | 8,000 W |
Running watts vs starting watts
Anything with a motor or compressor (fridge, freezer, pumps, air conditioners, furnace blower, power tools) draws two to three times its running power for a moment while it spins up. A generator has to cover that moment or it stalls and the appliance does not start. Heaters, kettles, toasters and lights draw the same power from the first second.
Manufacturers publish starting watts in two ways: as the total at start-up, or as the extra added on top of running watts. The calculator stores the total and uses the extra (total minus running) so the numbers line up whichever chart you are reading.
How to size a generator by hand
- List what must run together. Pick the appliances you need during the same hours, not everything in the house. A fridge, a sump pump and the furnace blower are the usual core of a backup plan.
- Add the running watts. Sum the running watts of every item, multiplied by how many you have.
- Add one starting surge. Find the single appliance with the largest extra starting watts and add only that surge. Motors start one at a time, so the surges do not stack.
- Leave headroom. Add about 20% to the peak and keep the continuous load under 80% of the generator rating, then round up to a size that is actually sold.
Size ≥ max( (Σ running + largest surge) × 1.2 , Σ running ÷ 0.8 )
Portable, inverter or standby
Portable (open frame) units of 3,000 to 9,500 W cover most essentials-only plans and are the cheapest per watt. Many have a 240 V outlet that a well pump or a transfer switch needs; check before you buy if either is on your list.
Inverter generators of 2,000 to 4,500 W are quieter and save fuel at light load, a good match for a fridge, lights and electronics.
Standby generators of 10 to 26 kW start automatically and can carry central air. They are wired permanently through an automatic transfer switch by an electrician.
However you connect it, never back-feed a home through a dryer outlet: it can energize the utility line and injure line workers. Use a transfer switch or an interlock kit.
Running a generator off batteries instead
For quiet overnight loads such as a fridge, a CPAP or Wi-Fi, a battery bank may beat a generator. Work out the capacity with the amp hour calculator and check how long it lasts with the battery runtime calculator.
Questions
What size generator do I need to run a house?
Essentials (fridge, lights, Wi-Fi, sump pump and furnace blower) peak at about 3,560 W, which points to a 4,500 W portable. Adding central air and an electric water heater pushes a typical home to about 17.5 kW, the range of standby generators wired in through a transfer switch.
What is the difference between starting and running watts?
Running watts are what an appliance draws once it is going. Starting (surge) watts are the short extra kick a motor or compressor needs for a second or two at start-up. Resistive loads such as heaters, toasters and light bulbs have no meaningful surge.
What will a 2,000 watt generator run?
A fridge, lights, a TV, Wi-Fi and phone chargers, one at a time with anything that has a heating element. It cannot start a 1/2 HP well pump (about 2,000 W at start) while other things are running, and it will not run a space heater and a microwave together.
Can a 3,500 watt generator run a refrigerator and a sump pump?
Yes. A newer fridge and a 1/2 HP sump pump run at about 1,450 W and peak near 2,550 W when the pump kicks on, inside a 3,500 W rating. Add the furnace blower and you are at the limit.
Is a generator rated in kW or kVA?
Home and portable generators are rated in watts or kW. Standby and commercial units are often also given in kVA; at the usual power factor of 0.8, a 10 kW generator is 12.5 kVA.
Do I need an inverter generator?
Only if you run sensitive electronics a lot or need quiet operation. Inverter generators produce cleaner power and throttle down at light load, but cost more per watt. For a fridge and pumps, a conventional generator works.
Appliance figures cross-checked against Champion Power Equipment's generator wattage chart, Lowe's portable generator wattage worksheet and Penn State's EGEE 102 appliance power ratings; details on how we calculate. Last checked November 2026.