- Home
- Appliance Wattage Chart
Appliance Wattage Chart
Running watts, starting watts and daily energy for 38 common appliances. Tick the ones you use, set the hours, and the chart totals the load, the kWh per day and the monthly cost.
A refrigerator runs at up to about 400 W (older models 700 W) and briefly needs 1,200 W or more to start. Heating appliances draw the most: a space heater 1,500 W, a water heater 4,500 W, an electric dryer 6,000 W.
| Use | Appliance | Running W | Starting W | Hours/day | kWh/day |
|---|---|---|---|---|---|
| Kitchen | |||||
| Refrigerator (newer, Energy Star) | 400 | 1,200 | 3.2 | ||
| Refrigerator (older, 10+ years) | 700 | 2,900 | 7 | ||
| Chest or upright freezer | 500 | 1,000 | 4 | ||
| Mini fridge | 100 | 600 | 0.8 | ||
| Microwave oven | 1,200 | – | 0.4 | ||
| Coffee maker | 1,200 | – | 0.4 | ||
| Toaster | 1,400 | – | 0.1 | ||
| Electric range, one burner | 2,400 | – | 2.4 | ||
| Dishwasher | 2,400 | – | 2.4 | ||
| Heating & cooling | |||||
| Furnace blower fan (1/2 HP) | 800 | 1,600 | 6.4 | ||
| Window AC, 5,000 BTU | 600 | 1,200 | 4.8 | ||
| Window AC, 10,000 BTU | 1,200 | 2,400 | 9.6 | ||
| Central AC, 3 ton | 3,500 | 6,000 | 28 | ||
| Space heater | 1,500 | – | 6 | ||
| Dehumidifier | 785 | – | 6.3 | ||
| Water | |||||
| Sump pump (1/3 HP) | 800 | 1,600 | 0.8 | ||
| Sump pump (1/2 HP) | 1,050 | 2,150 | 1.1 | ||
| Well pump (1/2 HP) | 1,000 | 2,000 | 1 | ||
| Well pump (1 HP) | 2,000 | 4,000 | 2 | ||
| Electric water heater | 4,500 | – | 13.5 | ||
| Laundry | |||||
| Washing machine | 1,000 | 2,300 | 1 | ||
| Electric clothes dryer | 6,000 | – | 6 | ||
| Clothes iron | 1,800 | – | 0.4 | ||
| Living | |||||
| TV, 32 to 55 in | 400 | – | 2 | ||
| Ceiling fan | 75 | – | 0.6 | ||
| Box or window fan | 200 | – | 1.6 | ||
| LED bulb (each) | 15 | – | 0.1 | ||
| Wi-Fi router and modem | 20 | – | 0.5 | ||
| Laptop or phone charger | 100 | – | 0.4 | ||
| Vacuum cleaner | 1,440 | – | 0.4 | ||
| Hair dryer | 1,875 | – | 0.4 | ||
| Medical & safety | |||||
| CPAP machine (no heated humidifier) | 60 | – | 0.5 | ||
| CPAP with heated humidifier | 120 | – | 1 | ||
| Home security system | 40 | – | 1 | ||
| Tools | |||||
| Air compressor (1 HP) | 1,500 | 4,500 | 0.8 | ||
| Circular saw, 7-1/4 in | 1,800 | 3,600 | 0.5 | ||
| Miter saw, 10 in | 1,800 | 3,600 | 0.5 | ||
| RV & camping | |||||
| RV air conditioner, 13,500 BTU | 2,000 | 3,500 | 12 | ||
Running watts are the upper end of typical ranges; starting watts appear only where a motor or compressor adds a surge. Hours per day are examples, set your own. Fridges, freezers and AC units cycle, so their kWh at full running watts overstates real use; a plug-in meter tells you the true figure.
Running watts, starting watts and kWh
Running watts are the steady draw while the appliance works. They decide how big a generator or inverter must be for continuous use.
Starting watts are the brief peak a motor needs to start, two to three times its running power for a second or two. Only one has to be covered at a time if you start appliances one by one, which is how the generator size calculator treats them.
kWh per day is watts × hours ÷ 1000. It sets your power bill and the size of a battery bank: one day of the ticked loads needs the amp hours shown in the bar above, and the amp hour calculator works out other voltages and battery types.
The biggest loads in a typical home
| Appliance | Running W | 1 hour costs |
|---|---|---|
| Electric clothes dryer | 6,000 | $1.02 |
| Electric water heater | 4,500 | $0.77 |
| Central AC, 3 ton | 3,500 | $0.60 |
| Electric range, one burner | 2,400 | $0.41 |
| Dishwasher | 2,400 | $0.41 |
| Well pump (1 HP) | 2,000 | $0.34 |
| RV air conditioner, 13,500 BTU | 2,000 | $0.34 |
| Hair dryer | 1,875 | $0.32 |
At $0.17 per kWh, close to the US residential average in 2025–2026; your bill shows your own rate.
Running appliances on batteries or solar
An inverter has to cover the running total of everything that is on and the starting surge of the largest motor, just as a generator does; most inverters list a surge rating for a few seconds that is about twice their continuous rating. Heating appliances are the hard part off-grid: a 1,500 W space heater empties a 12 V 100 Ah lithium battery in well under an hour, so off-grid homes heat with gas, wood or a heat pump and keep electric resistance loads short.
Reading the label yourself
Every appliance has a rating plate, usually on the back, inside the door or under the base. If it lists watts, that is the maximum draw. If it lists volts and amps, multiply them: 120 V × 6 A = 720 W. Motor plates also show horsepower; as a rough guide, a 1/2 HP motor runs at 800 to 1,000 W. The plate gives the worst case, so real average use is often lower, especially for anything with a thermostat.
For battery systems, check how long one charge covers these loads with the battery runtime calculator.
Questions
How many watts does a refrigerator use?
A newer Energy Star fridge runs at up to about 400 W while the compressor is on and needs around 1,200 W for a moment at start-up. An older fridge can run near 700 W and surge close to 2,900 W. Because the compressor cycles, the daily use is roughly 1 to 2 kWh, not running watts × 24.
What appliances use 500 watts or more?
Anything that heats or moves a lot of air or water: microwaves and coffee makers (about 1,200 W), toasters, space heaters (1,500 W), hair dryers, dishwashers, window AC units, pumps, and the big ones, electric water heaters (4,500 W) and dryers (6,000 W).
Is 400 watts a lot of electricity?
It depends on how long it runs. 400 W for one hour is 0.4 kWh, about $0.07 at 17 cents per kWh. Running all day it is 9.6 kWh, which would empty a 12 V 100 Ah battery about eight times over.
Can a 500 watt solar panel run a refrigerator?
Not on its own after sunset. A 500 W panel produces roughly 2 to 3 kWh on a sunny day, enough to cover a newer fridge, but you need a battery to carry the compressor through the night and an inverter that can handle its starting surge.
How can I measure what my appliance really uses?
Read the nameplate (watts, or volts × amps) for the maximum, then use a plug-in energy meter for a day to see the real average and kWh. For hard-wired loads such as pumps and furnaces, the motor label lists running amps; starting current is usually 2 to 3 times that.
Cross-checked against Champion Power Equipment's generator wattage chart, Lowe's portable generator wattage worksheet and Penn State's EGEE 102 table of appliance power ratings; see how we calculate. Last checked November 2026.